There are three types of installation for the micro switch lever. It determines the difficulty of changing a lever.
Positioning Insertion Type Lever, one of the simplest type to change
Step one, you can use a tool (like a paper-knife) to open the gap between the micro switch cover.
Step two, open the cover and take out the lever.
Step tree, used a new lever to change it and close the cover.
Generally, this kind of lever micro switches is a non-waterproof type, like our G5T series, G6 series microswitch.
Push Type Insertion Lever
Step one, used your knife to open the metal cover and take it off
Step two, used a new lever to push it in the right position
Tip: we need to take the lever off carefully to avoid damaging your microswitch case.
Some of the sealed waterproof micro switches are using this lever, like our G5W11, G9 series.
Total Insertion Type Lever
The type of this lever can’t be replaced or it will be damaged the construction.
Most of them are in a very small size, like our G3G10 series.
All in all, it is easy to change a micro switch lever but the total insertion type lever. Hey, Let’s do this.